The universal scanning solution – accurate high-speed scanning for all types of parts and applications.
The Romer Absolute Arm 7-Axis "SI" series with integrated laser scanner delivers the convenience of a fully integrated 3D scanning solution. The scanner is permanently incorporated into the seventh axis, and weight balanced with ROMER's Zero-G counterbalance feature for ergonomics and ease of use. The feature pack contains the scanner interface, so no external controller box is required. Single button automatic laser power control allows scanning of different surface types. No warm up time coupled with no homing procedures means an operator can be up and scanning in just moments.
ROMER Absolute Arm with integrated scanner is the first portable arm system in the market that is factory calibrated and certified to B89 specifications.
The ROMER Absolute Arm Scanner 73 and 75 series offer two different levels of performance and features to suit most inspection requirements.
| 73-Series | 75-Series | |
| Absolute Encoders | Included | Included |
| Zero-G Counterbalance with Lock | Included | Included |
| SpinGrips | N/A | Included |
| TESA TKJ Connector | Included | Included |
| 3 TESA Hard Probes | Included | Included |
| Integrated Scanner | Included | Included |
| Feature Pack | ROMER Scanning Pack | ROMER Scanning Pack |
| Digital Camera | N/A | N/A |
| LED Worklight | N/A | N/A |
| Certified Calibration Sphere | Included | Included |
| NIST Traceable Length Standard Bar | Optional | Included |
| Hard Case | Included | Included |
| Dust Cover | Included | Included |
| Base | Bolt-down base plate | Magnetic |
| Travel Case | Included | Included |
| Application Software For Inspection: or For Reverse Engineering: |
Included PC-DMIS Scanning or PC-DMIS Reshaper |
Included PC-DMIS Scanning or PC-DMIS Reshaper |
| Utility Software | RDS | RDS |
| Factory Calibration and Certification according to B89.4.22* | Included | Included |
* Hexagon Scanners only
7-Axis ROMER Absolute Arm with Integrated Scanner Probing and Scanning Specifications – 73 series
| Model3 | Measuring Range | Probing Point Repeatability1 |
Probing Volumetric Accuracy2 |
Scanning System Accuracy4 (with RS1) |
Arm Weights |
|
7320SI |
2.0 m / 6.6 ft. | ± 0.044 mm / 0.0017 in. | ± 0.061 mm / 0.0024 in. | 0.079 mm / 0.0031 in | 8.3 kg / 18.3 lbs. |
|
7325SI |
2.5 m / 8.2 ft. | ± 0.049 mm / 0.0019 in. | ± 0.069 mm / 0.0027 in. | 0.084 mm / 0.0033 in. | 8.6 kg / 19.0 lbs. |
|
7330SI |
3.0 m / 9.8 ft. | ± 0.085 mm / 0.0033 in. | ± 0.110 mm / 0.0043 in. | 0.119 mm / 0.0047 in. | 8.9 kg / 19.6 lbs. |
|
7335SI |
3.5 m / 11.5 ft. | ± 0.108 mm / 0.0043 in. | ± 0.136 mm / 0.0054 in. | 0.147 mm / 0.0058 in. | 9.2 kg / 20.3 lbs. |
|
7340SI |
4.0 m / 13.1 ft. | ± 0.120 mm / 0.0047 in. | ± 0.168 mm / 0.0066 in. | 0.181 mm / 0.0071 in. | 9.5 kg / 20.9 lbs. |
|
7345SI |
4.5 m / 14.8 ft. | ± 0.156 mm / 0.0061 in. | ± 0.198 mm / 0.0078 in. | 0.214 mm / 0.0084 in. | 9.8 kg / 21.6 lbs. |
7-Axis Romer Absolute Arm with Integrated Scanner Probing and Scanning Specifications – 75 series
| Model3 | Measuring Range | Probing Point Repeatability1 |
Probing Volumetric Accuracy2 |
Scanning System Accuracy4 (with RS1) |
Arm Weights |
|
7520SI |
2.0 m / 6.6 ft. | ± 0.023 mm / 0.0009 in. | ± 0.033 mm / 0.0013 in. | 0.058 mm / 0.0023 in. | 8.6 kg / 19.0 lbs. |
|
7525SI |
2.5 m / 8.2 ft. | ± 0.028 mm / 0.0011 in. | ± 0.039 mm / 0.0015 in. | 0.063 mm / 0.0025 in. | 8.9 kg / 19.6 lbs. |
|
7530SI |
3.0 m / 9.8 ft. | ± 0.048 mm / 0.0019 in. | ± 0.066 mm / 0.0026 in. | 0.083 mm / 0.0033 in. | 9.2 kg / 20.3 lbs. |
|
7535SI |
3.5 m / 11.5 ft. |
± 0.061 mm / 0.0024 in. |
± 0.093 mm / 0.0037 in. |
0.101 mm / 0.0040 in. |
9.5 kg / 20.9 lbs. |
|
7540SI |
4.0 m / 13.1 ft. | ± 0.074 mm / 0.0029 in. | ± 0.106 mm / 0.0042 in. | 0.119 mm / 0.0047 in. | 9.8 kg / 21.6 lbs. |
|
7545SI |
4.5 m / 14.8 ft. | ± 0.088 mm / 0.0035 in. | ± 0.126 mm / 0.0050 in. | 0.138 mm / 0.0054 in. | 10.1 kg / 22.3 lbs. |
All specifications according to B89.4.22.
1 The Point Repeatability Test is the reference test to determine measurement arm repeatability with ball probe. The cone is in front of the machine. Points are measured from multiple approach directions. The average point and the deviation of each point to the average center are calculated. The result is the maximum range divided by two.
2 The Volumetric Accuracy Test is the most representative test for volume measurement accuracy. A gage block with a known and certified length is measured several times throughout the working volume. This gage block is installed in different positions and measured depending on multiple approach directions. The result is the maximum deviation of the measuring distance less the theoretical length.
3 SI designates the ROMER Absolute Arm with integrated scanner.
4 The Scanning System Accuracy Test most accurately represents the reasonable expectations for machine performance in practical measuring applications while using the laser scanning method. The test consists of measuring a matte grey sphere with 5 different arm articulations. In each articulation of the arm the sphere is scanned from 5 different directions such that the majority of the sphere is scanned. The result is the maximum 3D center to center distance of the 5 spheres.
Ambient conditions:
Marks of conformity:
Power requirement:
ROMER Integrated Scanner Sensor Specifications
| Integrated Scanner RS1 | |
| Max. Point acquisition rate | 30,000 Points/s |
| Points per Line | 1000 |
| Line Rate | 30 Hz |
| Line width | 65 mm / 2.56 in |
| Stand off | 150mm ± 50 mm / 5.8in ± 1.97in |
| Point spacing (min) | 0.046 mm / 0.0018 in |
| Laser power control | Semi-automatic – per line |
| Accuracy (2 sigma)1 | 30 µm / 0.0012 in |
| Weight | 340 g /11.99 ounces |
| Controller | No |
| Laser Safety | Class 2M |
| Working temperature | 5°C – 40°C (41°F – 104°F) |
1 The sensor accuracy is defined as the deviation of the XY location of a calibration artifact through the measuring range of the sensor.
All probing specifications are achieved with a ROMER Absolute Arm mounted on a ROMER base plate or magnetic base and using a 15 mm steel ball probe with a length of 50 mm under stable environmental conditions.
All CMS 108 scanning specifications are achieved with a ROMER Absolute Arm mounted on a ROMER base plate or magnetic base and using CMS 108 zoom setting 2A (mid range scan width 60 mm and point spacing 0.03 mm) and a matte grey calibration sphere 25.4mm diameter under stable environmental conditions.
All RS1 scanning specifications are achieved with a ROMER Absolute Arm mounted on a ROMER base plate or magnetic base and a matte grey calibration sphere of 25.4 mm diameter under stable environmental conditions.
![]()
Click Here to download the ROMER Absolute Arm brochure.
In North America, Schedule Online to arrange a demonstration or call 800.218.7125.
Hexagon Metrology
250 Circuit Drive
North Kingstown, RI 02852
Toll Free: 800.218.7125
Phone: 401.886.2770
Fax: 248.449.9445
| Part of Hexagon Group | © 2012 Hexagon Metrology, Inc. | All Rights Reserved | Privacy Statement | Terms of Use | Site Map |